Pentair EasyTouch 8 and 4 User Manual.Pentair easy touch manual

Looking for:

Pentair easy touch manual 













































   

 

Pentair easy touch manual.Pentair Control Manuals



  WebThe EasyTouch® Control System family offers a new level of control for homeowner's looking for an affordable, easy to use pool/spa control system. EasyTouch allows full . WebPool Automation that is Simple and Affordable. The EasyTouch Control System eliminates the inconvenience of trips to your pool equipment pad, memorizing operating sequences, . WebPRODUCT MANUALS AND GUIDES Product owners manuals are available for nearly every product to help you and your pool professional install and service your pool and .  

Pentair easy touch manual.Download Center | Pentair



  WebOct 4,  · EasyTouch Wireless Control Panel Installation and User’s Guide 11 Setting up the EasyTouch wireless control panel for the first time Setting up the EasyTouch wireless . WebJan 31,  · Pool School: How to Program Your Pentair Easytouch Automation by Presidential Pools, Spas & Patio Presidential Pools, Spas & Patio K subscribers . WebPool Automation that is Simple and Affordable. The EasyTouch Control System eliminates the inconvenience of trips to your pool equipment pad, memorizing operating sequences, . WebPRODUCT MANUALS AND GUIDES Product owners manuals are available for nearly every product to help you and your pool professional install and service your pool and . WebThe EasyTouch® Control System family offers a new level of control for homeowner's looking for an affordable, easy to use pool/spa control system. EasyTouch allows full .    

 

EasyTouch Pool & Spa Control Systems | Pentair.Pentair easy touch manual



   

Table Of Contents. Quick Links. Table of Contents. Previous Page. Next Page. Control Systems Pentair EasyTouch 8 and 4 Installation Manual Pool and spa control system with optional intellichlor electronic chlorine generator 32 pages. ET Fax: Web sites visit www. Page 3: Table Of Contents Schedule start and stop times for equipment Page 4 System Test This Guide provides installation and operation instructions for the product.

This product is intended for use in swimming pool applications only. All work must be performed by a licensed electrician, and must conform to all national, state, and local codes. Install to provide drainage of compartment for electrical components. If this system is used to control underwater lighting fixtures, a ground-fault interrupter GFCI must be provided for these fixtures. This version is limited to chapter 1 to chapter 11 by specified firmware controlled in the U.

Instruction to user - This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. The indoor control panel is connected to the Power Center enclosure. Page 13 F button to switch off the pump, only the heater will turn off, then the filter pump will automatically switch off after 10 minutes to allow the heater to cool down.

Pentair Water Pool and Spa heaters do not require a cool down time. Page 14 When this button is pressed the solar relay is switched on to activate a booster pump, if installed, and activates valves to rotate to divert water through solar heating panels. Press the button again to switch the filter pump off LED off. Page 18 Control panel buttons are disabled while in menu mode.

If there has been no button activity for 60 seconds see page Page 20 Set the cover aside. Orient the positive polarity end of each battery as shown below. Heating your Spa manual control Heating the spa water on demand is easy, just press the SPA button to switch the heater on. The spa or pool water will heat to the settings specified. The system will use the heating source that is selected. Page Controlling Lights You can set timers schedules to automatically run equipment for pool filtration or turn on or off lights.

Up to four 4 total system programs may be created for all circuits combined. The generic circuit names are: Spa, Pool, Aux , Feature You can set this timer feature for other equipment such as lighting, spa, or spa jets. Configure the heater system options page 30 Set the type of heat source being used Heater, Solar, Solar Preferred. Once you have checked that all buttons operate properly, place labels on remote buttons.

Lights and laminars can also be scheduled to switch on and off at specific times. Page Setting Up Lights Setting up Lights Continued From the Lights screen you can manually switch all lights on or off, synchronize colored lights, and activate From the Lights screen you can manually switch all lights on or off, synchronize colored lights, and activate color light shows.

Fixed light colors are selected and activated from the Colors screen. IntelliBrite Light: If the light was not previously on, after selecting the fixed colored light, no illumination will occur for approximately six 6 seconds followed by the selection. The 12 VAC powered LED light can generate a series of multicolored light shows, or can be set to display a continuous, single color. Each time a MagicStream laminar feature is activated, it resumes with the same features in operation as when last switched off.

Heaters manufactured by Pentair Water Pool and Spa do not require this cool-down period and do not need the delay to be set up. Page Schedules Menu Schedules Menu Use the Schedules menu to create programs to schedule start and stop times to automatically run equipment, such as pumps and lights. Any circuit can be programmed to switch on and off at a specific time on every or any specific day of the week.

The time period is from one minute to 24 hours or run continuously. The system clock settings are used for the system scheduled operations. Right button: Move to RPM to change the pump speed. Page 45 Before assigning a pump address, first set the address on the pump itself. In this case you do not need to set the pump address. To calculate the Saturation Index, you must first test the pool water for pH, temperature, calcium hardness, and total alkalinity.

This setting moves By assigning AUX circuits to control valve actuators, you can conserve auxiliary circuits for high voltage relays for controlling pumps and lights. Select Yes or No to enable solar as a heat pump. If Solar is set to heat pump, Valve A is free for other circuits. You can also add an additional sensor for controlling solar heating systems. Generally, these sensors are accurate and you do not have to calibrate them.

However, long plumbing runs and water features can cause temperatures at a body of water to be different from the temperature sensor reading. Any optional controllers will need to be reconfigured. Page Settings Menu: Power Save Wireless Controller Note: If the unit is not used for 60 default seconds the power save function switches off the unit.

Follow the on-screen prompts to perform the tests. The following lists the sensor errors. If after performing a control panel self test see page 55 there were no errors detected, Code 0 is displayed, indicating that there were no problems and the test was successful. PSL4 Control System circuit board. Symptom Possible Cause Solution Bad wiring run from Verify cable and ensure no connections are broken. Page 71 II Wireless Remote will not work, or will not work dependably. The See the wiring table below for the pin configuration.

For UltraTemp Heat Pump setup information, see page Third party registered and unregistered trademarks and logos are the property of their respective owners. This manual is also suitable for: Easytouch psl4. Print page 1 Print document 80 pages. Rename the bookmark. Delete bookmark? Cancel Delete. Delete from my manuals? Sign In OR. Don't have an account? Sign up! Restore password. Upload manual. Upload from disk. Upload from URL.